APC Netshelter SX Racks

APC Netshelter SX Racks
Netshelter
Home — PartnersAPC — APC Netshelter SX Racks

APC Netshelter SX enclosures have a front door perforated area which is optimized with a curved profile to provide greater surface area and allowance of more perforation coverage and higher perforation rating. Simple selection — no need to spend hours choosing from and compiling dozens of part numbers to create a single enclosure. With APC they has made it easy by handling the details and providing complete enclosures with single part numbers. Enclosure adjustment tools and hardware provided — all enclosures are provided standard with hardware bag that includes hardware for mounting IT equipment and tools for simple enclosure adjustment. Cable access openings with pre-installed brushes — large cable access slots in the roof provides access for overhead cable egress. The bottom design allows for unobstructed cable access through a raised floor. Roof includes openings with brush strips pre-installed in locations biased towards the front of the enclosure.

Racks and enclosures for IT equipment from network closets to data centers. APC Critical Power & Cooling Services (CPCS) provides the expertise, services, and support you need for your building, industry, power, or data center infrastructure. Use APC world-class services which offers a smart way to protect your equipment, ensuring that your system is always operating at peak performance, thereby prolonging its lifespan. Together we can develop a solution to maximize system availability, increase efficiency, and meet your budget. Refer to enclosure user documentation for detailed specifications on eyebolt requirements and enclosure weight limits. Equipment mounting rails integrate with patch cabling systems-equipment mounting rails include zero U mounting holes beside the EIA 19″ mounting space that allow the installation of Data Distribution Cable (DDC) patch systems without taking up any critical equipment U—space.

[embedyt] https://www.youtube.com/embed?listType=playlist&list=PLCFA70B8B2CED0B81&layout=gallery%5B/embedyt%5D

APC NetShelter SX

Feature-rich rack enclosure optimized for easy installation, managing cables, integrating power distribution, and maximizing airflow. Easily removable cable access roof can be removed with simple pull-pin hinges for access during equipment installation or even with cabling already in place and routed through the cable openings. Once removed the roof is reversible to reposition the larger cable openings for power distribution plugs and connectors. Half-height side panels and option with brush strips for pass-through — half-height quick release side panels reduce size and weight for easy handling and access to equipment. Side panels are lockable utilizing a single key with the doors. Now available are side panel options integrated with pass-through holes and brush strips for routing cabling to adjacent racks in a row while still maintaining proper airflow. Quick release doors — front door can be moved to the opposite side.

Agility And Safety

Special packaging options for shipping APC Netshelter rack with equipment mounted — enclosures with shock packaging are standard enclosures with provisions in the packaging design and enclosure assembly for shipping the enclosures with equipment mounted inside. Check apc.com for enclosure size options and availability. Integrated joining hardware with multiple width enclosure alignment — enclosures include pre-installed joining hardware to join enclosures in a row and provide additional stability to the enclosure. The pre-installed joining hardware includes holes for joining to an adjacent enclosure at 600mm centers or 24in centers depending upon the floor layout. Integrated electrical grounding — the roof, side panels and front and rear doors are grounded to the frame of the enclosure. Eight additional electrical grounding inserts are located on the frame for external grounding. Designed for enhanced structural stability — a proven frame design, heavy-gauge mounting rails, and heavy-duty casters provide for 3000 lb (1364 kg) static (leveling feet) and 2250 lb (1023 kg) dynamic (castor) load ratings.
Netshelter
[TABS_B id=20122]